期刊
RADIATION ONCOLOGY
卷 10, 期 -, 页码 -出版社
BMC
DOI: 10.1186/s13014-014-0316-1
关键词
Intra-operative electron radiation therapy; TachoSil; Haemostatic patch; Rectal cancer
资金
- Fundacao para a Ciencia e Tecnologia (FCT) [PTDC/SAU-ENB/117631/2010]
- Fundação para a Ciência e a Tecnologia [PTDC/SAU-ENB/117631/2010] Funding Source: FCT
Background: Surgery of locally advanced and/or recurrent rectal cancer can be complemented with intra-operative electron radiation therapy (IOERT) to deliver a single dose of radiation directly to the unresectable margins, while sparing nearby sensitive organs/structures. Haemorrhages may occur and can affect the dose distribution, leading to an incorrect target irradiation. The TachoSil (TS) surgical patch, when activated, creates a fibrin clot at the surgical site to achieve haemostasis. The aim of this work was to determine the effect of TS on the dose distribution, and ascertain whether it could be used in combination with IOERT. This characterization was extended to include high dose rate (HDR) intraoperative brachytherapy, which is sometimes used at other institutions instead of IOERT. Methods: CT images of the TS patch were acquired for initial characterization. Dosimetric measurements were performed in a water tank phantom, using a conventional LINAC with a hard-docking system of cylindrical applicators. Percentage Depth Dose (PDD) curves were obtained, and measurements made at the depth of dose maximum for the three clinically used electron energies (6, 9 and 12MeV), first without any attenuator and then with the activated patch of TS completely covering the tip of the IOERT applicator. For HDR brachytherapy, a measurement setup was improvised using a solid water phantom and a Farmer ionization chamber. Results: Our measurements show that the attenuation of a TachoSil patch is negligible, both for high energy electron beams (6 to 12MeV), and for a HDR Ir-192 brachytherapy source. Our results cannot be extrapolated to lower beam energies such as 50 kVp X-rays, which are sometimes used for breast IORT. Conclusion: The TachoSil surgical patch can be used in IORT procedures using 6MeV electron energies or higher, or HDR Ir-192 brachytherapy.
作者
我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。
推荐
暂无数据