Ultrashort pulsed laser ablation and stripping of freeze-dried dermis

期刊

LASERS IN MEDICAL SCIENCE
卷 25, 期 4, 页码 517-524

出版社

SPRINGER LONDON LTD
DOI: 10.1007/s10103-009-0741-9

关键词

Ultrafast laser; Plasma-mediated ablation; Tissue dissection; Freeze-dried dermis; Thermal damage

资金

  1. Musculoskeletal Transplant Foundation, Inc.

向作者/读者索取更多资源

Plasma-mediated laser ablation and dissection of freeze-dried human dermis using an ultrashort pulsed laser of pulse width 900 fs and wavelength 1,552 nm were investigated. The surface ablation line width and depth in relation to irradiation fluence and pulse overlap rate were characterized and measured by scanning electron microscopy. The ablation threshold fluence for freeze-dried dermis was determined as 8.32 J/cm(2) and the incubation factor subject to pulse train irradiation was found to be 0.54. Histological examination showed no thermal damage with single line ablation. Even with multiline ablation, thermal damage was insignificant and the lateral damage zone was generally within 10 A mu m with 100 continuously repeated line scans. Ultrashort pulsed laser ablation of the interior of dry dermal tissue was shown to strip thin dermal slices with different thicknesses ranging from 20 to 40 A mu m.