4.6 Article

Increased artery wall stress post-stenting leads to greater intimal thickening

期刊

LABORATORY INVESTIGATION
卷 91, 期 6, 页码 955-967

出版社

NATURE PUBLISHING GROUP
DOI: 10.1038/labinvest.2011.57

关键词

biomechanics; finite element method; pathobiology; restenosis; vascular pathology; vascular stent

资金

  1. NIH [R01 EB000115]

向作者/读者索取更多资源

Since the first human procedure in the late 1980s, vascular stent implantation has been accepted as a standard form of treatment of atherosclerosis. Despite their tremendous success, these medical devices are not without their problems, as excessive neointimal hyperplasia can result in the formation of a new blockage (restenosis). Clinical data suggest that stent design is a key factor in the development of restenosis. Additionally, computational studies indicate that the biomechanical environment is strongly dependent on the geometrical configuration of the stent, and, therefore, possibly involved in the development of restenosis. We hypothesize that stents that induce higher stresses on the artery wall lead to a more aggressive pathobiologic response, as determined by the amount of neointimal hyperplasia. The aim of this investigation was to examine the role of solid biomechanics in the development of restenosis. A combination of computational modeling techniques and in vivo analysis were employed to investigate the pathobiologic response to two stent designs that impose greater or lesser levels of stress on the artery wall. Stent designs were implanted in a porcine model (pigs) for approximately 28 days and novel integrative pathology techniques (quantitative micro-computed tomography, histomorphometry) were utilized to quantify the pathobiologic response. Concomitantly, computational methods were used to quantify the mechanical loads that the two stents place on the artery. Results reveal a strong correlation between the computed stress values induced on the artery wall and the pathobiologic response; the stent that subjected the artery to the higher stresses had significantly more neointimal thickening at stent struts (high-stress stent: 0.197 +/- 0.020 mm vs low-stress stent: 0.071 +/- 0.016 mm). Therefore, we conclude that the pathobiologic differences are a direct result of the solid biomechanical environment, confirming the hypothesis that stents that impose higher wall stresses will provoke a more aggressive pathobiological response. Laboratory Investigation (2011) 91, 955-967; doi:10.1038/labinvest.2011.57; published online 28 March 2011

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.6
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据