4.7 Article

Smart-phone based computational microscopy using multi-frame contact imaging on a fiber-optic array

期刊

LAB ON A CHIP
卷 13, 期 20, 页码 4015-4023

出版社

ROYAL SOC CHEMISTRY
DOI: 10.1039/c3lc50589h

关键词

-

资金

  1. Presidential Early Career Award for Scientists and Engineers (PECASE)
  2. ARO Young Investigator Award
  3. National Science Foundation (NSF) CAREER Award
  4. NSF CBET
  5. Office of Naval Research (ONR) Young Investigator Award
  6. National Institutes of Health (NIH) Director's New Innovator Award, Office of the Director, National Institutes of Health [DP2OD006427]
  7. Directorate For Engineering [0954482] Funding Source: National Science Foundation
  8. Div Of Chem, Bioeng, Env, & Transp Sys [0954482] Funding Source: National Science Foundation

向作者/读者索取更多资源

We demonstrate a cellphone based contact microscopy platform, termed Contact Scope, which can image highly dense or connected samples in transmission mode. Weighing approximately 76 grams, this portable and compact microscope is installed on the existing camera unit of a cellphone using an opto-mechanical add-on, where planar samples of interest are placed in contact with the top facet of a tapered fiber-optic array. This glass-based tapered fiber array has similar to 9 fold higher density of fiber optic cables on its top facet compared to the bottom one and is illuminated by an incoherent light source, e. g., a simple light-emitting-diode (LED). The transmitted light pattern through the object is then sampled by this array of fiber optic cables, delivering a transmission image of the sample onto the other side of the taper, with similar to 3x magnification in each direction. This magnified image of the object, located at the bottom facet of the fiber array, is then projected onto the CMOS image sensor of the cellphone using two lenses. While keeping the sample and the cellphone camera at a fixed position, the fiber-optic array is then manually rotated with discrete angular increments of e.g., 1-2 degrees. At each angular position of the fiber-optic array, contact images are captured using the cellphone camera, creating a sequence of transmission images for the same sample. These multi-frame images are digitally fused together based on a shift-and-add algorithm through a custom-developed Android application running on the smart-phone, providing the final microscopic image of the sample, visualized through the screen of the phone. This final computation step improves the resolution and also removes spatial artefacts that arise due to non-uniform sampling of the transmission intensity at the fiber optic array surface. We validated the performance of this cellphone based Contact Scope by imaging resolution test charts and blood smears.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.7
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据