4.7 Article

A dynamic multi-organ-chip for long-term cultivation and substance testing proven by 3D human liver and skin tissue co-culture

期刊

LAB ON A CHIP
卷 13, 期 18, 页码 3538-3547

出版社

ROYAL SOC CHEMISTRY
DOI: 10.1039/c3lc50234a

关键词

-

资金

  1. German Federal Ministry for Education and Research [0315569]
  2. Russian Ministry for Science [16.522.12.2015, 16.522.11.7057]

向作者/读者索取更多资源

Current in vitro and animal tests for drug development are failing to emulate the systemic organ complexity of the human body and, therefore, to accurately predict drug toxicity. In this study, we present a multi-organ-chip capable of maintaining 3D tissues derived from cell lines, primary cells and biopsies of various human organs. We designed a multi-organ-chip with co-cultures of human artificial liver microtissues and skin biopsies, each a 1/100 000 of the biomass of their original human organ counterparts, and have successfully proven its long-term performance. The system supports two different culture modes: i) tissue exposed to the fluid flow, or ii) tissue shielded from the underlying fluid flow by standard Transwell (R) cultures. Crosstalk between the two tissues was observed in 14-day co-cultures exposed to fluid flow. Applying the same culture mode, liver microtissues showed sensitivity at different molecular levels to the toxic substance troglitazone during a 6-day exposure. Finally, an astonishingly stable long-term performance of the Transwell (R)-based co-cultures could be observed over a 28-day period. This mode facilitates exposure of skin at the air-liquid interface. Thus, we provide here a potential new tool for systemic substance testing.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.7
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据