From sample to PCR product in under 45 minutes: a polymeric integrated microdevice for clinical and forensic DNA analysis

期刊

LAB ON A CHIP
卷 13, 期 7, 页码 1384-1393

出版社

ROYAL SOC CHEMISTRY
DOI: 10.1039/c3lc41326h

关键词

-

向作者/读者索取更多资源

The extraction and amplification of DNA from biological samples is laborious and time-consuming, requiring numerous instruments and sample handling steps. An integrated, single-use, poly(methyl methacrylate) (PMMA) microdevice for DNA extraction and amplification would benefit clinical and forensic communities, providing a completely closed system with rapid sample-in-PCR-product-out capability. Here, we show the design and simple flow control required for enzyme-based DNA preparation and PCR from buccal swabs or liquid whole blood samples with an similar to 5-fold reduction in time. A swab containing cells or DNA could be loaded into a novel receptacle together with the DNA liberation reagents, heated using an infrared heating system, mixed with PCR reagents for one of three different target sets under syringe-driven flow, and thermally-cycled in less than 45 min, an similar to 6-fold reduction in analysis time as compared to conventional methods. The 4 : 1 PCR reagents : DNA ratio required to provide the correct final concentration of all PCR components for effective amplification was verified using image analysis of colored dyes in the PCR chamber. Novel single-actuation, 'normally-open' adhesive valves were shown to effectively seal the PCR chamber during thermal cycling, preventing air bubble expansion. The effectiveness of the device was demonstrated using three target sets: the sex-typing gene Amelogenin, co-amplification of the beta-globin and gelsolin genes, and the amplification of 15 short tandem repeat (STR) loci plus Amelogenin. The use of the integrated microdevice was expanded to the analysis of liquid blood samples which, when incubated with the DNA liberation reagents, form a brown precipitate that inhibits PCR. A simple centrifugation of the integrated microchips (on a custom centrifuge), mobilized the precipitate away from the microchannel entrance, improving amplification of the b-globin and gelsolin gene fragments by similar to 6-fold. This plastic integrated microdevice represents a microfluidic platform with potential for evolution into point-of-care prototypes for application to both clinical and forensic analyses, providing a 5-fold reduction from conventional analysis time.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.7
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据