Microfluorimeter with disposable polymer chip for detection of coeliac disease toxic gliadin

期刊

LAB ON A CHIP
卷 9, 期 24, 页码 3535-3542

出版社

ROYAL SOC CHEMISTRY
DOI: 10.1039/b914635k

关键词

-

资金

  1. GENCAT
  2. ICREA Funding Source: Custom

向作者/读者索取更多资源

Coeliac disease is an inflammatory disease of the upper small intestine and results from gluten ingestion in genetically susceptible individuals, and is the only life-long nutrient-induced enteropathy. The only treatment is a strict gluten-free diet and the longer the individual fails to adhere to this diet, the greater the chance of developing malnutrition and other complications. The existence of reliable gluten free food is crucial to the well-being of the population. Here we report on a microfluorimeter device for the in situ detection of gliadin in foodstuffs, which could be used for a rapid control of raw materials in food processing, as well as for process control of gliadin contamination. The microfluorimeter is based on a reflector that is used inside a microfluidic chip, exploiting various strategically placed reflective or totally metallised mirrors for efficient collection of the fluorescent light emitted in a large solid angle. The chip is capable of executing five assays in parallel and has been demonstrated to possess detection sensitivity applicable to fluoroimmunoassays. Various immunoassay formats exploiting fluorescence detection, using enzyme/fluorophore labels were developed and compared in terms of sensitivity, ease of assay, assay time and compatibility with buffer used to extract gliadin from raw and cooked foodstuffs, with the best performance observed with an indirect competition assay using a fluorophore-labelled anti-mouse antibody. This assay was exploited within the microfluorimeter device, and a very low detection limit of 4.1 ng/mL was obtained. The system was observed to be highly reproducible, with an RSD of 5.9%, for a concentration of 50 ng/mL of gliadin applied to each of the five channels of the microfluorimeter. Biofunctionalised disposable strips incorporated into the microfluorimeter were subjected to accelerated Arrhenius thermal stability studies and it was demonstrated that strips pre-coated with gliadin could be stored for approximate to 2 years at 4 degrees C, with no discernable loss in sensitivity or detectability of the assay. Finally, the microfluorimeter was applied to the analysis of commercial gluten-free food samples, and an excellent correlation with routine ELISA measurements was obtained. The developed microfluorimeter should find widespread application for on-site execution of fluoroimmunoassays.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.7
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据