4.5 Article

The challenge of implant integration in partial meniscal replacement: an experimental study on a silk fibroin scaffold in sheep

期刊

出版社

SPRINGER
DOI: 10.1007/s00167-018-5160-7

关键词

Meniscus; Meniscectomy; Osteoarthritis; Meniscal replacement; Silk; Silk fibroin; Scaffold; Permanent replacement

资金

  1. German Armed Forces [E/U2AD/ED001/EF551]
  2. Wellcome Trust [100917/z/13/z]
  3. NIHR Invention for Innovation Programme (i4i) [II-LS-1010-100009]
  4. Innovate UK Regenerative Medicines Programme [102162]
  5. Wellcome Trust [100917/Z/13/Z] Funding Source: Wellcome Trust
  6. Innovate UK [102162] Funding Source: UKRI

向作者/读者索取更多资源

To restore meniscal function after excessive tissue damage, a silk fibroin implant for partial meniscal replacement was developed and investigated in an earlier sheep model. After 6 months implantation, it showed promising results in terms of chondroprotection and biocompatibility. To improve surgical fixation, the material was subjected to optimisation and a fibre mesh was integrated into the porous matrix. The aim of the study was the evaluation of this second generation of silk fibroin implants in a sheep model. Nine adult merino sheep received subtotal meniscal replacement using the silk fibroin scaffold. In nine additional animals, the defect was left untreated. Sham surgery was performed in another group of nine animals. After 6 months of implantation macroscopic, biomechanical and histological evaluations of the scaffold, meniscus, and articular cartilage were conducted. Macroscopic evaluation revealed no signs of inflammation of the operated knee joint and most implants were located in the defect. However, there was no solid connection to the remaining peripheral meniscal rim and three devices showed a radial rupture at the middle zone. The equilibrium modulus of the scaffold increased after 6 months implantation time as identified by biomechanical testing (before implantation 0.6 +/- 0.3 MPa; after implantation: 0.8 +/- 0.3 MPa). Macroscopically and histologically visible softening and fibrillation of the articular cartilage in the meniscectomy- and implant group were confirmed biomechanically by indentation testing of the tibial cartilage. In the current study, biocompatibility of the silk fibroin scaffold was reconfirmed. The initial mechanical properties of the silk fibroin implant resembled native meniscal tissue. However, stiffness of the scaffold increased considerably after implantation. This might have prevented integration of the device and chondroprotection of the underlying cartilage. Furthermore, the increased stiffness of the material is likely responsible for the partial destruction of some implants. Clinically, we learn that an inappropriate replacement device might lead to similar cartilage damage as seen after meniscectomy. Given the poor acceptance of the clinically available partial meniscal replacement devices, it can be speculated that development of a total meniscal replacement device might be the less challenging option.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.5
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据