4.4 Article

Validation of an internally controlled one-step real-time multiplex RT-PCR assay for the detection and quantitation of dengue virus RNA in plasma

期刊

JOURNAL OF VIROLOGICAL METHODS
卷 177, 期 2, 页码 168-173

出版社

ELSEVIER
DOI: 10.1016/j.jviromet.2011.08.002

关键词

Dengue virus; One step real time multiplex RT-PCR; Validation

资金

  1. Wellcome Trust [084368] Funding Source: Medline

向作者/读者索取更多资源

Dengue is mosquito-borne virus infection that annually causes similar to 50 million clinically apparent cases worldwide. An internally controlled one-step real-time multiplex RT-PCR assay was developed for detection and quantitation of DENV RNA in plasma sample by using specific primers and fluorogenic TaqMan probes. All primers and probes targeted sequences near the 3' end of the NS5 gene. The method comprised two multiplex assays and was validated for sensitivity, specificity, linearity, reproducibility and precision. An internal control template was spiked into each clinical specimen to provide quality assurance for each experimental step. The assay allowed for detection of between 0.5 and 3 infectious particles per mL, is rapid and has been operationally characterized in 287 Vietnamese dengue patients from two therapeutic intervention trials at the Hospital for Tropical Diseases, Ho Chi Minh City, Viet Nam. (C) 2011 Elsevier B.V. All rights reserved.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。