4.4 Article

Design and verification of a highly reliable Linear-After-The-Exponential PCR (LATE-PCR) assay for the detection of African swine fever virus

期刊

JOURNAL OF VIROLOGICAL METHODS
卷 172, 期 1-2, 页码 8-15

出版社

ELSEVIER
DOI: 10.1016/j.jviromet.2010.12.003

关键词

African swine fever virus (ASFV); Real-time PCR; Detection; Linear-After-The-Exponential (LATE)-PCR

资金

  1. Smiths Detection Diagnostics
  2. Swedish University of Agricultural Sciences
  3. EC [211691]
  4. EC FP7 network of Excellence EPI-ZONE

向作者/读者索取更多资源

African swine fever virus (ASFV) is a highly pathogenic DNA virus that is the causative agent of African swine fever (ASF), an infectious disease of domestic and wild pigs of all breeds and ages, causing a range of syndromes. Acute disease is characterized by high fever, haemorrhages in the reticuloendothelial system, and a high mortality rate. A powerful novel diagnostic assay based on the Linear-After-The-Exponential-PCR (LATE-PCR) principle was developed to detect ASFV. LATE-PCR is an advanced form of asymmetric PCR which results in direct amplification of large amount of single-stranded DNA. Fluorescent readings are acquired using endpoint analysis after PCR amplification. Amplification of the correct product is verified by melting curve analysis. The assay was designed to amplify the VP72 gene of ASFV genome. Nineteen ASFV DNA cell culture virus strains and three tissue samples (spleen, tonsil, and liver) from infected experimental pigs were tested. Virus was detected in all of the cell culture and tissue samples. None of five ASFV-related viruses tested produced a positive signal, demonstrating the high specificity of the assay. The sensitivity of the LATE-PCR assay was determined in two separate real-time monoplex reactions using samples of synthetic ASFV and synthetic control-DNA targets that were diluted serially from 10(9) to 1 initial copies per reaction. The detection limit was 1 and 10 copies/reaction, respectively. The sensitivity of the assay was also tested in a duplex end-point reactions comprised of a constant level of 150 copies of synthetic control-DNA and a clinical sample of spleen tissue diluted serially from 10(-1) to 10(-5). The detection limit was 10(-5) dilution which corresponds to approximately 1 copy/reaction. Since the assay is designed to be used in either laboratory settings or in a portable PCR machine (Bio-Seeq Portable Veterinary Diagnostics Laboratory; Smiths Detection, Watford UK), the LATE-PCR provides a robust and novel tool for the diagnosis of ASF both in the laboratory and in the field. (C) 2010 Elsevier B.V. All rights reserved.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.4
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据