BACKGROUND: Intracompartmental pressure measurements are frequently used in the diagnosis of compartment syndrome, particularly in patients with equivocal or limited physical examination findings. Little clinical work has been done to validate the clinical use of intracompartmental pressures or identify associated false-positive rates. We hypothesized that diagnosis of compartment syndrome based on one-time pressure measurements alone is associated with a high false-positive rate. METHODS: Forty-eight consecutive patients with tibial shaft fractures who were not suspected of having compartment syndrome based on physical examinations were prospectively enrolled. Pressure measurements were obtained in all four compartments at a single point in time immediately after induction of anesthesia using a pressure-monitoring device. Preoperative and intraoperative blood pressure measurements were recorded. The same standardized examination was performed by the attending surgeon preoperatively, postoperatively, and during clinical follow-up for 6 months to assess clinical evidence of acute or late compartment syndrome. RESULTS: No clinical evidence of compartment syndrome was observed postoperatively or during follow-up until 6 months after injury. Using the accepted criteria of delta P of 30 mm Hg from preoperative diastolic blood pressure, 35% of cases (n = 16; 95% confidence interval, 21.5-48.5%) met criteria for compartment syndrome. Raising the threshold to delta P of 20 mm Hg reduced the false-positive rate to 24% (n = 11; 95% confidence interval, 11.1-34.9%). Twenty-two percent (n = 10; 95% confidence interval, 9.5-32.5%) exceeded absolute pressure of 45 mm Hg. CONCLUSION: A 35% false-positive rate was found for the diagnosis of compartment syndrome in patients with tibial shaft fractures who were not thought to have compartment syndrome by using currently accepted criteria for diagnosis based solely on one-time compartment pressure measurements. Our data suggest that reliance on one-time intracompartmental pressure measurements can overestimate the rate of compartment syndrome and raise concern regarding unnecessary fasciotomies. Copyright (C) 2014 by Lippincott Williams & Wilkins

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.2
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据