The purpose of this study was to assess plasma selenium levels in an Australian blood donor population and measure extra-cellular selenium levels in fresh manufactured blood components. Selenium levels were measured using graphite furnace atomic absorption spectrometry with Zeeman background correction. The mean plasma selenium level in healthy plasmapharesis donors was 85.6 +/- 0.5 mu g/L and a regional difference was observed between donors in South East Queensland and Far North Queensland. Although participants had selenium levels within the normal range (55.3-110.5 mu g/L), 88.5% had levels below 100 mu g/L, a level that has been associated with sub-optimal activity of the antioxidant enzyme glutathione peroxidase (GPx). Extra-cellular selenium levels in clinical fresh frozen plasma (cFFP) and apheresis-derived platelets (APH Plt) were within the normal range. Packed red blood cells (PRBC) and pooled buffy coat-derived platelets (BC Plt) had levels at the lower limit of detection, which may have clinical implications to the massively transfused patient. Crown Copyright (C) 2013 Published by Elsevier GmbH. All rights reserved.