4.6 Article

Heparin-induced thrombocytopenia: towards standardization of platelet factor 4/heparin antigen tests

期刊

JOURNAL OF THROMBOSIS AND HAEMOSTASIS
卷 8, 期 9, 页码 2025-2031

出版社

ELSEVIER SCIENCE INC
DOI: 10.1111/j.1538-7836.2010.03974.x

关键词

heparin; heparin-induced thrombocytopenia; laboratory testing; platelets

资金

  1. Deutsche Forschungsgemeinschaft [1096/2-4, GRK-840]
  2. German Federal Ministry for Education and Research [CAN04/006]
  3. Novartis
  4. Heart and Stroke Foundation of Ontario [T-6157]

向作者/读者索取更多资源

Background: Laboratory confirmation of heparin-induced thrombocytopenia (HIT) is based on detection of heparin-dependent platelet-activating antibodies. Platelet factor 4 (PF4)/heparin enzyme-immunoassays (EIA) are a widely available surrogate for platelet-activating antibodies. Objective: Defining the optical density (OD) reactivity profiles of a PF4/heparin EIA in reference subject and patient populations and the correlation of the EIA results (expressed in OD units) with the prevalence of platelet-activating antibodies. Patients/methods: Using quantile regression we determined the 97.5th percentile of PF4/heparin-immunoglobulin G (IgG) EIA reactivities in non-heparin-treated individuals [blood donors (n = 935)] and patients before heparin therapy (n = 1207). In patients with suspected HIT, we compared the correlation of EIA-IgG reactivities (Greifswald laboratory; n = 2821) and the heparin-induced platelet activation assay (HIPA) with the correlation of reactivities of another EIA-IgG (McMaster laboratory; n = 1956) with the serotonin-release assay (SRA). Results: PF4/heparin-IgG EIA OD reactivities had a lower OD 97.5th percentile in blood donors compared with patient groups before heparin treatment (P < 0.001). The percentage of sera testing positive in the functional assays strongly correlated with PF4/heparin-IgG EIA OD reactivities in both laboratories with very similar results (correlation coefficient > 0.9) when normalized OD ranges (maximum OD divided by 10) were used instead of absolute OD values. Conclusions: Results of PF4/heparin-IgG EIA should not be reported as only positive or negative as there is no single acceptable cut-off value. Instead, reporting PF4/heparin-IgG EIA OD results in ranges allows for risk-stratified prediction for presence of platelet-activating antibodies. Use of normalized OD ranges permits a standardized approach for inter-laboratory comparisons.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.6
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据