4.6 Article

microRNAs Derived from Circulating Exosomes as Noninvasive Biomarkers for Screening and Diagnosing Lung Cancer

期刊

JOURNAL OF THORACIC ONCOLOGY
卷 8, 期 9, 页码 1156-1162

出版社

LIPPINCOTT WILLIAMS & WILKINS
DOI: 10.1097/JTO.0b013e318299ac32

关键词

Exosome; Screening test; Diagnostic test; Lung adenocarcinoma; microRNA

资金

  1. NCI Early Detection Research Network [2U01CA111295-04, U01CA086/37]

向作者/读者索取更多资源

Introduction: Lung cancer is the highest cause of mortality among tumor pathologies worldwide. There are no validated techniques for an early detection of pulmonary cancer lesions other than low-dose helical computed tomography scan. Unfortunately, this method has some negative effects. Recent studies have laid the basis for development of exosomes-based techniques to screen/diagnose lung cancers. As the isolation of circulating exosomes is a minimally invasive procedure, this technique opens new possibilities for diagnostic applications. Methods: We used a first set of 30 plasma samples from as many patients, including 10 patients affected by lung adenocarcinomas, 10 with lung granulomas, and 10 healthy smokers matched for age and sex as negative controls. Wide-range microRNAs analysis (742 microRNAs) was performed by quantitative real time polymerase chain reaction. Data were compared on the basis of lesion characteristics, using WEKA software for statistics and modeling. Subsequently, selected microRNAs were evaluated on an independent larger group of samples (105 specimens: 50 lung adenocarcinomas, 30 lung granulomas, and 25 healthy smokers). Results: This analysis led to the selection of four microRNAs to perform a screening test (miR-378a, miR-379, miR-139-5p, and miR-200b-5p), useful to divide population into two groups: nodule (lung adenocarcinomas + carcinomas) and non-nodule (healthy former smokers). Six microRNAs (miR-151a-5p, miR-30a-3p, miR-200b-5p, miR-629, miR-100, and miR-154-3p) were selected for a second test on the nodule population to discriminate between lung adenocarcinoma and granuloma. Conclusions: The screening test showed 97.5% sensitivity, 72.0% specificity, and area under the curve receiver operating characteristic of 90.8%. The diagnostic test had 96.0% sensitivity, 60.0% specificity, and area under the curve receiver operating characteristic of 76.0%. Further evaluation is needed to confirm the predictive power of these models on larger cohorts of samples.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.6
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据