4.6 Article

Semiquantification and Classification of Local Pulmonary Function by V/Q Single Photon Emission Computed Tomography in Patients with Non-small Cell Lung Cancer Potential Indication for Radiotherapy Planning

期刊

JOURNAL OF THORACIC ONCOLOGY
卷 6, 期 1, 页码 71-78

出版社

ELSEVIER SCIENCE INC
DOI: 10.1097/JTO.0b013e3181f77b40

关键词

Non-small cell lung cancer; Ventilation; Perfusion; Single photon emission computerized tomography; Radiotherapy

资金

  1. ASCO-CDA
  2. [R21CA127057]
  3. [P01CA059827]
  4. [SDWS-2007QW036]
  5. [BS2009YY012]
  6. NATIONAL CANCER INSTITUTE [R21CA127057, R01CA142840, P01CA059827] Funding Source: NIH RePORTER

向作者/读者索取更多资源

Introduction: Perfusion (Q) single photon emission computed tomography (SPECT) has been used to divert dose away from higher-functioning lung during radiation therapy (RT) planning. This study aimed to (1) study regional lung function through coregistered pulmonary ventilation/perfusion (V/Q)-SPECT-CT and (2) classify these defects for its potential value in radiation planning in patients with non-small cell lung cancer (NSCLC). Methods: Patients with stages I to III NSCLC requiring radiation-based therapy were eligible for this prospective study. V/Q-SPECT performed within 2 weeks before the start of radiation was interpreted by nuclear medicine physicians and then measured by a semiquantitative score. The potential mechanism of V and Q defects was analyzed; the potential impact of V/Q-SPECT over Q-SPECT alone was completed through classified applications (high-dose RT versus RT avoidance) during planning. Results: Images of 51 consecutive patients were analyzed. The V and Q defects were matched, reverse mismatched (V defect > Q defect), and mismatched (Q defect > V defect) in 61, 31, and 8% of patients, respectively. Tumor was the leading cause of the defects of ipsilateral lung in 73% of patients. The defect scores of the ipsilateral lung were greater in patients with central primaries than those with peripheral primaries for both V-SPECT (2.3 +/- 1.1 versus 1.5 +/- 0.8, p = 0.017) and Q-SPECT (2.2 +/- 0.8 versus 1.4 +/- 0.6, p = 0.000). The patients with chronic obstructive pulmonary disease had greater defect scores in contralateral lung for both V-SPECT (1.5 +/- 0.7 versus 1.0 +/- 0.8, p = 0.006) and Q-SPECT (1.4 +/- 0.6 versus 1.0 +/- 0.4, p = 0.010). On assessing the potential value of SPECT on RT plan, 39% of patients could have their RT plan when applying V/Q-SPECT rather than Q-SPECT alone. Conclusions: V/Q-SPECT provides a more comprehensive functional assessment, may provide additional value over Q-SPECT alone in assessing local pulmonary function, and guide RT plan decisions in patients with NSCLC.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.6
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据