4.6 Article

Restricted cusp motion in right-left type of bicuspid aortic valves: A new risk marker for aortopathy

期刊

出版社

MOSBY-ELSEVIER
DOI: 10.1016/j.jtcvs.2011.10.014

关键词

-

资金

  1. Second University of Naples, Italy

向作者/读者索取更多资源

Objective: Bicuspid aortic valve disease is heterogeneous with respect to valve morphology and aortopathy risk. This study searched for early imaging predictors of aortopathy in patients with a bicuspid aortic valve with right-left coronary cusp fusion, the most common morphotype. Methods: Time-resolved magnetic resonance imaging was performed in 36 subjects with nonstenotic, nonregurgitant bicuspid aortic valves and nondilated aortas and in 10 healthy controls with tricuspid aortic valves. Sinus dimensions (diameter, width, and height), ascending tract diameters, and wall strain were measured for each sinus/leaflet unit and corresponding ascending tract area to account for asymmetries. A novel parameter, cusp opening angle,'' measured the degree of valve leaflet alignment to outflow axis in systole, quantifying cusp motility. Phase-contrast magnetic resonance imaging and computational fluid dynamic models assessed flow patterns. Aortic growth rate was estimated over a follow-up period ranging from 9 to 84 months. Results: The expected restriction of bicuspid aortic valve opening (conjoint cusp opening angle, 62 degrees +/- 5 degrees vs 76 degrees +/- 3 degrees for nonfused leaflet and 75 degrees +/- 3 degrees for tricuspid aortic valve cusps; P < .001) was confirmed, and the introduced parameter reproducibly quantified this phenomenon. Phase-contrast magnetic resonance imaging demonstrated systolic flow deflection toward the right, affecting the right anterolateral ascending wall. Computational models confirmed that restricted cusp motion alone is sufficient to cause the observed flow pattern. Ascending tract wall strain was not circumferentially homogeneous in bicuspid aortic valves. In multivariable analyses, the conjoint cusp opening angle independently predicted ascending aorta diameters and growth rate (P < .001). Conclusions: In the bicuspid aortic valve commonly defined as normofunctional by echocardiographic criteria, restricted systolic conjoint cusp motion causes flow deflection. The novel measurement introduced can quantify restricted cusp opening, possibly assuming prognostic importance. (J Thorac Cardiovasc Surg 2012;144:360-9)

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.6
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据