4.5 Article

Experimental research on heat transfer of pulsating heat pipe

期刊

JOURNAL OF THERMAL SCIENCE
卷 17, 期 2, 页码 181-185

出版社

SCIENCE CHINA PRESS
DOI: 10.1007/s11630-008-0181-z

关键词

pulsating heat pipe; influence factors; performance of heat transfer

向作者/读者索取更多资源

Experimental research was conducted to understand heat transfer characteristic of pulsating heat pipe in this paper, and the PHP is made of high quality glass capillary tube. Under different fill ratio, heat transfer rate and many other influence factors, the flow patterns were observed in the start-up, transition and stable stage. The effects of heating position on heat transfer were discussed. The experimental results indicate that no annular flow appears in top heating condition. Under different fill ratios and heat transfer rate, the flow pattern in PHP is transferred from bulk flow to semi-annular flow and annular flow, and the performance of heat transfer is improved for down heating case. The experimental results indicate that the total heat resistant of HIP is increased with fill ratio, and heat transfer rate achieves optimum at filling rate 50%. But for pulsating heat pipe with changing diameters the thermal resistance is higher than that with uniform diameters.