4.7 Article

Correlation analysis of sample thickness, heat flux, and cone calorimetry test data of polystyrene foam

期刊

JOURNAL OF THERMAL ANALYSIS AND CALORIMETRY
卷 119, 期 1, 页码 229-238

出版社

SPRINGER
DOI: 10.1007/s10973-014-4165-9

关键词

Polystyrene; Cone calorimeter; Sample thickness effect; Ignition time; Heat release rate; Correlation analysis

资金

  1. National Basic Research Program of China (973 Program) [2012CB719702]
  2. Research Fund for the Doctoral Program of Higher Education [20113402110023]
  3. National Natural Science Foundation of China [51036007, 51206002]
  4. Key Technologies R&D Program of China during the 12th Five-Year Plan Period [2013BAJ01B05]
  5. Anhui University of Technology [QZ201109]
  6. State Key Laboratory of Fire Science [HZ2012-KF04, HZ2012-KF08]

向作者/读者索取更多资源

This paper deals with thermal and fire performance evaluation of expanded polystyrene (EPS) and extruded polystyrene (XPS) in a cone calorimeter with a piloted ignition. The correlation analysis of sample thickness, heat flux (q) over dot '', and experimental results is performed. It is found that the heat flux follows a linear function of the vertical distance from the standard horizontal level to the sample. An optimization ignition model is established considering the effects of sample thickness (or radiant distance). The modified ignition time ((t) over bar (ig)) decreases with the increase of the sample thickness. Both t(ig) (ignition time) and (t) over bar (ig) drop as external heat flux rises. EPS's t(ig) is more sensitive to the variation of external heat flux. Thermal thickness (delta(P)) decreases with the intensifying of heat flux, and delta(P) is in linear correlation with rho/(q) over dot ''. When sample is quite thin or the irradiance level is low (2 cm-thick PS under 35 kW m(-2) and 3 cm-thick EPS under 25 kW m(-2)), single peak heat release rate (HRR) is present. Under other situations, there are at least two peak values. For EPS, the first peak value is higher than the last, while the reverse is true for XPS (exclusive of 5 cm-thick XPS at 35 kW m(-2)). Both peak and mean HRR rise linearly with the increase of external heat flux. t(ig), (t) over bar (ig), critical heat flux and delta(P) of XPS are smaller than those of EPS, while the reverse is true for mean HRR. The ignition and heat release risk of PS drop with the decrease of external heat flux, and these hazards of XPS are higher than those of EPS.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.7
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据