期刊
JOURNAL OF THE BRAZILIAN CHEMICAL SOCIETY
卷 21, 期 4, 页码 620-626出版社
SOC BRASILEIRA QUIMICA
DOI: 10.1590/S0103-50532010000400006
关键词
GF AAS; biodiesel; microemulsion; cadmium; lead; thallium; chemical modifier
资金
- Conselho Nacional de Desenvolvimento Cientifico e Tecnologico (CNPq, Brasilia, Brazil)
- Fundacao de Apoio a Pesquisa Cientifica e Tecnologica do Estado de Santa Catarina (FAPESC, Florianopolis, Brazil)
Different calibration approaches and modifiers were tested for Cd, Pb and Tl determination in biodiesel by graphite furnace atomic absorption spectrometry (GF AAS). Microemulsions were prepared by mixing 2 g of biodiesel, 1 mL of a 10% (v/v) nitric acid aqueous solution and n-propanol to a 10 mL final volume. Pyrolysis temperatures of 600 degrees C for Cd and Tl with Pd as permanent modifier, and 800 degrees C for Pb with Ru as permanent modifier were used. Atomization temperatures were also optimized. Calibration solution prepared in aqueous medium did not correct non-spectral interferences, but matrix matching calibration using base oil led to accurate results with recoveries from 80 to 116%. The RSD values were lower than 8% for Cd and Pb and the LOD values were 0.5 ng g(-1) for Cd, 6 ng g(-1) for Pb and 1 ng g(-1) for Tl. The obtained results using the analyte additions method or by matrix matching calibration were in agreement, confirming the accuracy of the proposed procedure. Organometallic standards were not required and different samples were analyzed.
作者
我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。
推荐
暂无数据