4.4 Article

Accuracy of computer-aided design/computer-aided manufacturing-generated dental casts based on intraoral scanner data

期刊

JOURNAL OF THE AMERICAN DENTAL ASSOCIATION
卷 145, 期 11, 页码 1133-1140

出版社

AMER DENTAL ASSOC
DOI: 10.14219/jada.2014.87

关键词

Intraoral scanner; digital impression; milling; stereolithography; dental casts; accuracy; precision; trueness

向作者/读者索取更多资源

Background. Little is known about the accuracy of physical dental casts that are based on three-dimensional (3D) data from an intraoral scanner (IOS). Thus, the authors conducted a study to evaluate the accuracy of full-arch stereolithographic (SLA) and milled casts obtained from scans of three IOSs. Methods. The authors digitized a polyurethane model using a laboratory reference scanner and three IOSs. They sent the scans (n = five scans per IOS) to the manufacturers to produce five physical dental casts and scanned the casts with the reference scanner. Using 3D evaluation software, the authors superimposed the data sets and compared them. Results. The mean trueness values of Lava Chairside Oral Scanner C.O.S. (3M ESPE, St. Paul, Minn.), CEREC AC with Bluecam (Sirona, Bensheim, Germany) and iTero (Align Technology, San Jose, Calif.) casts were 67.50 micrometers (95 percent confidence interval [CI], 63.43-71.56), 75.80 mu m (95 percent CI, 71.74-79.87) and 98.23 mu m (95 percent CI, 94.17-102.30), respectively, with a statistically significant difference among all of the scanners (P < .05). The mean precision values were 13.77 mu m (95 percent CI, 2.76-24.79), 21.62 mu m (95 percent CI, 10.60-32.63) and 48.83 mu m (95 percent CI, 37.82-59.85), respectively, with statistically significant differences between CEREC AC with Bluecam and iTero casts, as well as between Lava Chairside Oral Scanner C.O.S. and iTero casts (P < .05). Conclusion. All of the casts showed an acceptable level of accuracy; however, the SLA-based casts (CEREC AC with Bluecam and Lava Chairside Oral Scanner C.O.S.) seemed to be more accurate than milled casts (iTero). Practical Implications. On the basis of the results of this investigation, the authors suggested that SLA technology was superior for the fabrication of dental casts. Nevertheless, all of the investigated casts showed clinically acceptable accuracy. Clinicians should keep in mind that the highest deviations might occur in the distal areas of the casts.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.4
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据