4.7 Article

Reproducibility of Echocardiographic Techniques for Sequential Assessment of Left Ventricular Ejection Fraction and Volumes Application to Patients Undergoing Cancer Chemotherapy

期刊

出版社

ELSEVIER SCIENCE INC
DOI: 10.1016/j.jacc.2012.09.035

关键词

3D echocardiography; chemotherapy; interobserver test re-test variability; interobserver variability; longitudinal variability

向作者/读者索取更多资源

Objectives The aim of this study was to identify the best echocardiographic method for sequential quantification of left ventricular (LV) ejection fraction (EF) and volumes in patients undergoing cancer chemotherapy. Background Decisions regarding cancer therapy are based on temporal changes of EF. However the method for EF measurement with the lowest temporal variability is unknown. Methods We selected patients in whom stable function in the face of chemotherapy for breast cancer was defined by stability of global longitudinal strain (GLS) at up to 5 time points (baseline, 3, 6, 9, and 12 months). In this way, changes in EF were considered to reflect temporal variability of measurements rather than cardiotoxicity. A comprehensive echocardiogram consisting of 2-dimensional (2D) and 3-dimensional (3D) acquisitions with and without contrast administration was performed at each time point. Stable LV function was defined as normal GLS (<=-16.0%) at each examination. The EF and volumes were measured with 2D-biplane Simpson's method, 2D-triplane, and 3-dimensional echocardiography (3DE) by 2 investigators blinded to any clinical data. Inter-, intra-, and test-retest variability were assessed in a subgroup. Variability was assessed by analysis of variance and compared with Levene's or t test. Results Among 56 patients (all female, 54 +/- 13 years of age), noncontrast 3D EF, end-diastolic volume, and end-systolic volume had significantly lower temporal variability than all other methods. Contrast only decreased the temporal variability of LV end-diastolic volume measurements by the 2D biplane method. Our data suggest that a temporal variability in EF of 0.06 might occur with noncontrast 3DE due to physiological differences and measurement variability, whereas this might be >0.10 with 2D methods. Overall, 3DE also had the best intra-and inter-observer as well as test-retest variability. Conclusions Noncontrast 3DE was the most reproducible technique for LVEF and LV volume measurements over 1 year of follow-up. (J Am Coll Cardiol 2013;61:77-84) (C) 2013 by the American College of Cardiology Foundation

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.7
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据