4.7 Article

Pulsatile Hemodynamics in Patients With Exertional Dyspnea Potentially of Value in the Diagnostic Evaluation of Suspected Heart Failure With Preserved Ejection Fraction

期刊

JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY
卷 61, 期 18, 页码 1874-1883

出版社

ELSEVIER SCIENCE INC
DOI: 10.1016/j.jacc.2013.02.013

关键词

arterial stiffness; arterial wave reflections; exertional dyspnea; heart failure with preserved ejection fraction; pulsatile hemodynamics

资金

  1. government of Lower Austria and European Funds for Regional Development (EFRE) [WST3-T-81/015-2008]
  2. Aortic Wrap
  3. Merck
  4. Novartis Pharmaceuticals

向作者/读者索取更多资源

Objectives This study sought to test whether measures of pulsatile arterial function are useful for diagnosing heart failure with preserved ejection fraction (HFPEF), in comparison with and in addition to tissue Doppler echocardiography (TDE). Background Increased arterial stiffness and wave reflections are present in most patients with HFPEF. Methods Patients with dyspnea as a major symptom were categorized as having HFPEF or no HFPEF, based on invasively derived filling pressures and natriuretic peptide levels. Pulse wave velocity (PWV) was measured invasively (aortic PWV). Aortic pulse pressure (aoPP) and its components (incident pressure wave height, forward wave amplitude; augmented pressure; backward wave amplitude [Pb]) were quantified noninvasively. Results Seventy-one patients were classified as HFPEF and 65 as no HFPEF (223 patients had intermediate results). Patients with HFPEF were older, more often had hypertension and diabetes, and had larger left atria and higher left ventricular mass. Brachial pulse pressure (bPP), aoPP, and all measures of arterial stiffness and wave reflections were higher in HFPEF patients. Receiver-operating curve analysis-derived area under the curve (AUC) values for separating HFPEF from no HFPEF were 0.823 for E/E'=at the medial annulus, the best TDE parameter; 0.816 for bPP; and 0.867, 0.851, and 0.825 for aortic PWV, aoPP, and Pb, respectively. Adding measures of pulsatile function to TDE resulted in an increase in AUC to 0.875 (bPP; p = 0.03) and 0.901 (aoPP; p = 0.005). In comparison with a TDE-based algorithm, net reclassification improvement was 32.9% (p < 0.0001). Conclusions Measures of pulsatile arterial hemodynamics may complement TDE for the diagnosis of HFPEF. (Pulsatile and Steady State Hemodynamics in Diastolic Heart Failure; NCT00720525) (C) 2013 by the American College of Cardiology Foundation

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.7
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据