4.7 Article

Treatment of Atrial Fibrillation by the Ablation of Localized Sources CONFIRM (Conventional Ablation for Atrial Fibrillation With or Without Focal Impulse and Rotor Modulation) Trial

期刊

出版社

ELSEVIER SCIENCE INC
DOI: 10.1016/j.jacc.2012.05.022

关键词

ablation; atrial fibrillation; electrical rotors; focal beats; multiwavelet reentry; therapy

资金

  1. National Institutes of Health [HL70529, HL83359, HL83359-S1]
  2. Doris Duke Charitable Foundation
  3. Direct For Mathematical & Physical Scien
  4. Division Of Physics [1308264] Funding Source: National Science Foundation

向作者/读者索取更多资源

Objectives We hypothesized that human atrial fibrillation (AF) may be sustained by localized sources (electrical rotors and focal impulses), whose elimination (focal impulse and rotor modulation [FIRM]) may improve outcome from AF ablation. Background Catheter ablation for AF is a promising therapy, whose success is limited in part by uncertainty in the mechanisms that sustain AF. We developed a computational approach to map whether AF is sustained by several meandering waves (the prevailing hypothesis) or localized sources, then prospectively tested whether targeting patient-specific mechanisms revealed by mapping would improve AF ablation outcome. Methods We recruited 92 subjects during 107 consecutive ablation procedures for paroxysmal or persistent (72%) AF. Cases were prospectively treated, in a 2-arm 1:2 design, by ablation at sources (FIRM-guided) followed by conventional ablation (n = 36), or conventional ablation alone (n = 71; FIRM-blinded). Results Localized rotors or focal impulses were detected in 98 (97%) of 101 cases with sustained AF, each exhibiting 2.1 +/- 1.0 sources. The acute endpoint (AF termination or consistent slowing) was achieved in 86% of FIRM-guided cases versus 20% of FIRM-blinded cases (p < 0.001). FIRM ablation alone at the primary source terminated AF in a median 2.5 min (interquartile range: 1.0 to 3.1 min). Total ablation time did not differ between groups (57.8 +/- 22.8 min vs. 52.1 +/- 17.8 min, p = 0.16). During a median 273 days (interquartile range: 132 to 681 days) after a single procedure, FIRM-guided cases had higher freedom from AF (82.4% vs. 44.9%; p < 0.001) after a single procedure than FIRM-blinded cases with rigorous, often implanted, electrocardiography monitoring. Adverse events did not differ between groups. Conclusions Localized electrical rotors and focal impulse sources are prevalent sustaining mechanisms for human AF. FIRM ablation at patient-specific sources acutely terminated or slowed AF, and improved outcome. These results offer a novel mechanistic framework and treatment paradigm for AF. (Conventional Ablation for Atrial Fibrillation With or Without Focal Impulse and Rotor Modulation [CONFIRM]; NCT01008722) (J Am Coll Cardiol 2012;60:628-36) (C) 2012 by the American College of Cardiology Foundation

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.7
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据