4.7 Article

Cross-Sectional Computed Tomographic Assessment Improves Accuracy of Aortic Annular Sizing for Transcatheter Aortic Valve Replacement and Reduces the Incidence of Paravalvular Aortic Regurgitation

期刊

JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY
卷 59, 期 14, 页码 1275-1286

出版社

ELSEVIER SCIENCE INC
DOI: 10.1016/j.jacc.2011.11.045

关键词

aortic annulus; aortic stenosis; computed tomography; paravalvular aortic regurgitation; transcatheter aortic valve implantation; transcatheter aortic valve replacement

资金

  1. Abbott
  2. Medtronic
  3. Lilly
  4. Johnson Johnson
  5. Daiichi Sankyo
  6. St. Jude Medical

向作者/读者索取更多资源

Objectives In an effort to define the gold standard for annular sizing for transcatheter aortic valve replacement (TAVR), we sought to critically analyze and compare the predictive value of multiple measures of the aortic annulus for post-TAVR paravalvular (PV) regurgitation and then assess the impact of a novel cross-sectional computed tomographic (CT) approach to annular sizing. Background Recent studies have shown clear discrepancies between conventional 2-dimensional (2D) echocardiographic and CT measurements. In terms of aortic annular measurement for TAVR, such findings have lacked the outcome analysis required to inform clinical practice. Methods The discriminatory value of multiple CT annular measures for post-TAVR PV aortic regurgitation was compared with 2D echocardiographic measures. TAVR outcomes with device selection according to aortic annular sizing using a traditional 2D transesophageal echocardiography-guided or a novel CT-guided approach were also studied. Results In receiver-operating characteristic models, cross-sectional CT parameters had the highest discriminatory value for post-TAVR PV regurgitation: This was with the area under the curve for [maximal cross-sectional diameter minus prosthesis size] of 0.82 (95% confidence interval: 0.69 to 0.94; p < 0.001) and that for [circumference-derived cross-sectional diameter minus prosthesis size] of 0.81 (95% confidence interval: 0.7 to 0.94; p < 0.001). In contrast, traditional echocardiographic measures were nondiscriminatory in relation to post-TAVR PV aortic regurgitation. The prospective application of a CT-guided annular sizing approach resulted in less PV aortic regurgitation of grade worse than mild after TAVR (7.5% vs. 21.9%; p = 0.045). Conclusions Our data lend strong support to 3-dimensional cross-sectional measures, using CT as the new gold standard for aortic annular evaluation for TAVR with the Edwards SAPIEN device. (J Am Coll Cardiol 2012;59:1275-86) (C) 2012 by the American College of Cardiology Foundation

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.7
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据