4.7 Article

Changes in Renal Function After Implantation of Continuous-Flow Left Ventricular Assist Devices

期刊

出版社

ELSEVIER SCIENCE INC
DOI: 10.1016/j.jacc.2011.09.038

关键词

assist device; heart failure; outcome; predictors; renal dysfunction

资金

  1. Thoratec Corporation

向作者/读者索取更多资源

Objectives The aim of this study was to determine renal outcomes after left ventricular assist device (LVAD) implantation. Background Renal dysfunction before LVAD placement is frequent, and it is unclear whether it is due to primary renal disease or to poor perfusion. Methods A retrospective single-center analysis was conducted in 83 consecutive patients implanted with HeartMate II continuous-flow LVADs (Thoratec Corp., Pleasanton, California). Calculated glomerular filtration rate (GFR) was assessed on admission and 1, 3, and 6 months after implantation. To define predictors for improvement in GFR, clinical variables were examined in patients with decreased renal function (GFR <60 ml/min/1.73 m(2)) before LVAD, surviving and dialysis-free at 1 month (n = 44). Results GFR significantly increased from admission (53.2 +/- 21.4 ml/min/1.73 m(2)) to 1 month after LVAD implantation (87.4 +/- 27.9 ml/min/1.73 m(2)) (P < 0.0001). Subsequently, at 3 and 6 months, GFR remained significantly (p < 0.0001) above pre-LVAD values. Of the 51 patients with GFRs < 60 ml/min/1.73 m(2) before LVAD surviving at 1 month, 34 (67%) improved to GFRs >60 ml/min/1.73 m(2). Univariate pre-operative predictors for improvement in renal function at 1 month included younger age (p = 0.049), GFR improvement with optimal medical therapy (p < 0.001), intra-aortic balloon pump use (p = 0.004), kidney length above 10 cm (p = 0.023), no treatment with angiotensin-converting enzyme inhibitors or angiotensin receptor blockers (p = 0.029), higher bilirubin (p = 0.002), higher Lietz-Miller score (p = 0.019), and atrial fibrillation (p = 0.007). Multivariate analysis indicated pre-operative improved GFR (slope = 0.5 U per unit improved; 95% confidence interval: 0.2 to 0.8; p = 0.003), atrial fibrillation (slope = 27; 95% confidence interval: 8 to 46; p = 0.006), and intra-aortic balloon pump use (slope = 14; 95% confidence interval: 2 to 26; p = 0.02) as independent predictors. Conclusions In most patients with end-stage heart failure considered for LVAD implantation, renal dysfunction is reversible and likely related to poor renal perfusion. (J Am Coll Cardiol 2012; 59: 26-36) (C) 2012 by the American College of Cardiology Foundation

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.7
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据