4.8 Article

Porous Coordination Polymer Hybrid Device with Quartz Oscillator: Effect of Crystal Size on Sorption Kinetics

期刊

JOURNAL OF THE AMERICAN CHEMICAL SOCIETY
卷 133, 期 31, 页码 11932-11935

出版社

AMER CHEMICAL SOC
DOI: 10.1021/ja205082p

关键词

-

资金

  1. DAAD
  2. Grants-in-Aid for Scientific Research [10J02257] Funding Source: KAKEN

向作者/读者索取更多资源

A new strategy to synthesize mono dispersed porous coordination polymer (PCP) nanocrystals at room temperature was developed and utilized for the formation of PCP thin films on gold substrates with fine control over the crystal sizes using the coordination modulation method. Hybridization of these PCP thin films with an environment-controlled quartz crystal microbalance system allowed determining the adsorption properties for organic vapors (methanol and hexane). In the case of high sensitivity (at the low-concentration dosing of analytes), the sensor response depended on the crystal size but not on the type of analyte. In contrast, at the high-concentration dosing, a clear dependence of the sorption kinetics on the analyte was observed due to significant sorbate-sorbate interaction.