4.2 Article

Implementation of a beam deflection system for studies of liquid interfaces on beamline I07 at Diamond

期刊

JOURNAL OF SYNCHROTRON RADIATION
卷 19, 期 -, 页码 408-416

出版社

WILEY-BLACKWELL
DOI: 10.1107/S0909049512009272

关键词

X-ray reflectivity; GIXD; GISAXS; air-water; liquid-liquid

向作者/读者索取更多资源

X-ray optics, based on a double-crystal deflection scheme, that enable reflectivity measurements from liquid surfaces/interfaces have been designed, built and commissioned on beamline I07 at Diamond Light Source. This system is able to deflect the beam onto a fixed sample position located at the centre of a five-circle diffractometer. Thus the incident angle can be easily varied without moving the sample, and the reflected beam is tracked either by a moving Pilatus 100K detector mounted on the diffractometer arm or by a stationary Pilatus 2M detector positioned appropriately for small-angle scattering. Thus the system can easily combine measurements of the reflectivity from liquid interfaces (Qz > 1 angstrom-1) with off-specular data collection, both in the form of grazing-incidence small-angle X-ray scattering (GISAXS) or wider-angle grazing-incidence X-ray diffraction (GIXD). The device allows operation over the energy range 1028 keV.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.2
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据