4.5 Review

Systematic review with meta-analysis of studies comparing intraoperative neuromonitoring of recurrent laryngeal nerves versus visualization alone during thyroidectomy

期刊

JOURNAL OF SURGICAL RESEARCH
卷 188, 期 1, 页码 152-161

出版社

ACADEMIC PRESS INC ELSEVIER SCIENCE
DOI: 10.1016/j.jss.2013.12.022

关键词

Thyroidectomy; Recurrent laryngeal nerve RLN; Intraoperative neuromonitoring IONM; Recurrent laryngeal nerve visualization RLN VA; Recurrent laryngeal nerve palsy

类别

资金

  1. University of Cagliari, Italy [CAR 2012]

向作者/读者索取更多资源

Background: The role of intraoperative neuromonitoring (IONM) of the recurrent laryngeal nerve (RLN) during thyroid surgery is still debatable. The aim of this meta-analysis was to evaluate the potential improvement of IONM versus RLN visualization alone (VA) in reducing the incidence of vocal cord palsy. Methods: A literature search for studies comparing IONM versus VA during thyroidectomy was performed. Studies were reviewed for primary outcome measures: overall, transient, and permanent RLN palsy per nerve and per patients at risk; and for secondary outcome measures: operative time; overall, transient and permanent RLN palsy per nerve at low and high risk; and the results regarding assistance in RLN identification before visualization. Results: Twenty studies comparing thyroidectomy with and without IONM were reviewed: three prospective, randomized trials, seven prospective trials, and ten retrospective, observational studies. Overall, 23,512 patients were included, with thyroidectomy performed using IONM compared with thyroidectomy by VA. The total number of nerves at risk was 35,513, with 24,038 nerves (67.7%) in the IONM group, compared with 11,475 nerves (32.3%) in the VA group. The rates of overall RLN palsy per nerve at risk were 3.47% in the IONM group and 3.67% in the VA group. The rates of transient RLN palsy per nerve at risk were 2.62% in the IONM group and 2.72% in the VA group. The rates of permanent RLN palsy per nerve at risk were 0.79% in the IONM group and 0.92% and in the VA group. None of these differences were statistically significant, and no other differences were found. Conclusions: The current review with meta-analysis showed no statistically significant difference in the incidence of RLN palsy when using IONM versus VA during thyroidectomy. However, these results must be approached with caution, as they were mainly based on data coming from non-randomized observational studies. Further studies including high-quality multicenter, prospective, randomized trials based on strict criteria of standardization and subsequent clustered meta-analysis are required to verify the outcomes of interest. (C) 2014 Elsevier Inc. All rights reserved.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.5
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据