4.5 Article

Measurements of the flow of supercritical carbon dioxide through short orifices

期刊

JOURNAL OF SUPERCRITICAL FLUIDS
卷 88, 期 -, 页码 17-25

出版社

ELSEVIER
DOI: 10.1016/j.supflu.2014.01.008

关键词

Supercritical carbon dioxide; Orifice; Two-phase flow; Discharge coefficient; Critical flow; Choked flow

资金

  1. U.S. Department of Energy Nuclear Energy University Programs [11-1625]

向作者/读者索取更多资源

This paper describes the methods used to measure flow rate of supercritical and two-phase CO2 through short orifices. Orifices with diameters of 1 millimeter and orifice length-to-diameter ratios of 3.2 and 5 were tested. Flow rates through these orifices were measured over a broad range of inlet conditions in the supercritical region with orifice inlet pressures ranging from 5 MPa to 11 MPa and inlet densities ranging from 86.5 kg/m(3) to 630 kg/m(3). The data were compared to the isentropic real gas model for expansion of a fluid through a nozzle in order to observe the behavior of the discharge coefficient. For a given orifice inlet condition, the single-phase discharge coefficient was found to be between 0.81 and 0.87 and was independent of the pressure ratio. The discharge coefficient increased as the pressure ratio decreased when two-phase CO2 was present with orifice inlet pressures of 7.7 MPa and 9 MPa. The critical mass flow rate and critical pressure ratio were determined for each test. The raw data from this investigation are available on the internet. This paper describes the methods used to measure flow of supercritical and two-phase CO2 through short orifices. Orifices with diameters of 1 millimeter and orifice length-to-diameter ratios of 3.2 and 5 were tested. Flow rates through these orifices were measured over a broad range of inlet conditions in the supercritical region with orifice inlet pressures ranging from 7.7 MPa to 11 MPa and inlet densities ranging from 111 kg/m(3) to 630 kg/m(3). The data were compared to the isentropic real gas model for expansion of a fluid through a nozzle in order to observe the behavior of the discharge coefficient. For a given orifice inlet condition, the single-phase discharge coefficient was found to be between 0.81 and 0.87 and was independent of the pressure ratio. The discharge coefficient increased as the pressure ratio decreased when two-phase CO2 was present with orifice inlet pressures of 7.7 MPa and 9 MPa. The critical mass flow rate and critical pressure ratio were determined for each test. The raw data from this investigation are available on the internet. Published by Elsevier B.V.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.5
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据