4.5 Review

Gas chromatography/mass spectrometry (GC/MS) remains a pre-eminent discovery tool in clinical steroid investigations even in the era of fast liquid chromatography tandem mass spectrometry (LC/MS/MS)

期刊

出版社

PERGAMON-ELSEVIER SCIENCE LTD
DOI: 10.1016/j.jsbmb.2010.04.010

关键词

Gas chromatography/mass spectrometry; GC/MS; Tandem mass spectrometry; P450 oxidoreductase deficiency; ORD; Apparent cortisone reductase deficiency; ACRD

资金

  1. Wellcome Trust [GR079865MA]
  2. Medical Research Council UK [0900567]
  3. BBSRC [BB/G023468/1] Funding Source: UKRI
  4. Biotechnology and Biological Sciences Research Council [BB/G023468/1] Funding Source: researchfish
  5. National Institute for Health Research [NF-SI-0508-10356] Funding Source: researchfish

向作者/读者索取更多资源

Liquid chromatography tandem mass spectrometry (LC/MS/MS) is replacing classical methods for steroid hormone analysis. It requires small sample volumes and has given rise to improved specificity and short analysis times. Its growth has been fueled by criticism of the validity of steroid analysis by older techniques, testosterone measurements being a prime example. While this approach is the gold-standard for measurement of individual steroids, and panels of such compounds, LC/MS/MS is of limited use in defining novel metabolomes. GC/MS, in contrast, is unsuited to rapid high-sensitivity analysis of specific compounds, but remains the most powerful discovery tool for defining steroid disorder metabolomes. Since the 1930s almost all inborn errors in steroidogenesis have been first defined through their urinary steroid excretion. In the last 30 years, this has been exclusively carried out by GC/MS and has defined conditions such as AME syndrome, glucocorticoid remediable aldosteronism (GRA) and Smith-Lemli-Opitz syndrome. Our recent foci have been on P450 oxidoreductase deficiency (ORD) and apparent cortisone reductase deficiency (ACRD). In contrast to LC/MS/MS methodology, a particular benefit of GC/MS is its non-selective nature: a scanned run will contain every steroid excreted, providing an integrated picture of an individual's metabolome. The Achilles heel of clinical GC/MS profiling may be data presentation. There is lack of familiarity with the multiple hormone metabolites excreted and diagnostic data are difficult for endocrinologists to comprehend. While several conditions are defined by the absolute concentration of steroid metabolites, many are readily diagnosed by ratios between steroid metabolites (precursor metabolite/product metabolite). Our work has led us to develop a simplified graphical representation of quantitative urinary steroid hormone profiles and diagnostic ratios. (C) 2010 Elsevier Ltd. All rights reserved.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.5
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据