3.9 Article

Accuracy and Safety Assessment of Pedicle Screw Placement Using the Rapid Prototyping Technique in Severe Congenital Scoliosis

期刊

JOURNAL OF SPINAL DISORDERS & TECHNIQUES
卷 24, 期 7, 页码 444-450

出版社

LIPPINCOTT WILLIAMS & WILKINS
DOI: 10.1097/BSD.0b013e318201be2a

关键词

rapid prototyping; spine; congenital scoliosis; spinal instrumentation; pedicle screw

向作者/读者索取更多资源

Study Design: The application of rapid prototyping (RP) technique for improving accuracy of pedicle screw placement in congenital scoliosis is described in this study. Objective: To compare the accuracy and safety of pedicle screw placement in congenital scoliosis using the RP technique versus the conventional fluoroscopy. Summary of Background Data: Mal developed vertebral components in congenital scoliosis leads to prolonged operation time and higher rate of screw misplacement. RP technique can enhance preoperative and perioperative planning. No data are available on the accuracy of pedicle screw fixation using the RP technique. Methods: Sixty-two consecutive patients with hemivertebra had undergone posterior-only hemivertebra resection. Pedicle screws were implanted either by the conventional intraoperative fluoroscopy technique (C-arm group; n = 28) or the RP technique (RP group; n = 34). Accuracy of pedicle screw placement was compared by postoperative computed tomographic scan. Results: Seventy of 677 inserted screws were found to be misplaced, showing an overall accuracy of 89.7% (90.8% in the thoracic spine and 87.4% in the lumbar spine). In the C-arm group, 86.1% (167 of 194) and 82.0% (82 of 100) of screws were accurately placed in the thoracic and lumbar spine, respectively. While in the RP group, the respective screw placement accuracies were 94.4% (238 of 252) and 91.6% (120 of 131). In the C-arm and the RP groups, 94.8% (279 of 294) and 97.9% (375 of 383) of the screws were within the safety zone, respectively. Compared with the fluoroscopy method, the RP-assisted technique showed a shorter operation time and higher scoliosis correction rate. No neurovascular-related complication was observed with this technique during the study. Conclusion: The application of RP technique in congenital scoliosis can reduce the operation time, the risk of screw misplacement and its consequent complications. The use of RP technique in congenital scoliosis is safe and efficacious.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

3.9
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据