期刊
JOURNAL OF SEPARATION SCIENCE
卷 37, 期 22, 页码 3347-3353出版社
WILEY-V C H VERLAG GMBH
DOI: 10.1002/jssc.201400778
关键词
Dispersive liquid-liquid microextraction; High-performance liquid chromatography; Pollutants; Sudan Red dyes
资金
- National Natural Science Foundation of China [21377167]
- Science Foundation of China University of Petroleum, Beijing [KYJJ2012-01-15]
Sudan Red pollutants have gained more attention in recent years. The present study described a simple and sensitive determination method for Sudan Red pollutants with dispersive liquid-liquid microextraction coupled to high-performance liquid chromatography. Chlorobenzene and ethanol were used as the extraction solvent and disperser solvent, respectively. The possible parameters such as the kind of solvents, ionic strength, and sample pH that could affect the enrichment have been optimized. Under the optimal conditions, the pollutants have been well enriched and the linear ranges of Sudan Red I and II were in the range of 0.3-40 mu g/L, and the linear ranges of Sudan Red III and IV were in the range of 1.2-160 mu g/L. The detection limits were in the range of 0.18-0.46 mu g/L, and the precisions were in the range of 3.7-5.9%. All these demonstrated that the proposed method could be a good alternative for the routine analysis of Sudan Red pollutants in water samples.
作者
我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。
推荐