期刊
JOURNAL OF SEPARATION SCIENCE
卷 36, 期 24, 页码 3883-3888出版社
WILEY-V C H VERLAG GMBH
DOI: 10.1002/jssc.201300771
关键词
Formaldehyde; GC-MS; Solid-phase microextraction; Vaccines
资金
- Research Council of Razi Vaccine and Research Institute (RVSRI)
A headspace solid-phase microextraction method coupled to GC-MS was successfully developed for the trace determination of formaldehyde in veterinary bacterial and human vaccines, and diphtheria-tetanus antigen. The formaldehyde was derivatized by means of the Hantzsch reaction prior to extraction and subsequent determination. Three different types of solid-phase microextraction fibers, polar, and nonpolar poly(dimethylsiloxane) and polyethylene glycol were prepared by using a sol-gel technique. The effects of different parameters such as type of fiber coating, extraction time and temperature, desorption conditions, agitation rate, and salt effect were investigated. Under the optimized conditions, the detection limit of the method was 979 ng/L using the selected ion-monitoring mode. The interday and intraday precisions of the developed method under the optimized conditions were below 13%, and the method shows linearity in the range of 1.75-800 g/L with a correlation coefficient of 0.9963. The optimized method was applied to the determination of formaldehyde from some biological products. The results were satisfactory compared to the standard method.
作者
我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。
推荐