期刊
JOURNAL OF SEPARATION SCIENCE
卷 36, 期 14, 页码 2348-2357出版社
WILEY-V C H VERLAG GMBH
DOI: 10.1002/jssc.201300204
关键词
Cordyceps sinensis; HPLC; Matrix solid-phase dispersion; Nucleo-bases; Nucleosides
Nine nucleosides and nucleobases, including uracil, adenine, thymine, uridine, adenosine, thymidine, cytidine, guanosine, and cordycepin in natural Cordyceps sinensis, cultured Cordyceps mycelia, and Cordyceps fruiting bodies were extracted by matrix solid-phase dispersion (MSPD) and determined by HPLC. The experimental conditions for the MSPD extraction were optimized. Florisil was used as dispersant, petroleum ether as washing solvent, and methanol as elution solvent. The Florisil-to-sample ratio was selected to be 4:1 and no additional clean-up sorbent was needed. The calibration curves had good linear relationships (r > 0.9997). The LOD and LOQ were in the range of 12 similar to 79 and 41 similar to 265 ng/mL, respectively. The intra- and interday precision were lower than 8.3%. The recoveries were between 61.5 and 93.2%. The present method consumed less sample compared with ultrasonic extraction and heating reflux extraction (HRE). The extraction yields obtained by using the present method are much higher than those obtained by UE and comparable to those obtained by HRE.