4.5 Article

Application of pneumatic nebulization single-drop microextraction for the determination of organophosphorous pesticides by gas chromatography-mass spectrometry

期刊

JOURNAL OF SEPARATION SCIENCE
卷 34, 期 15, 页码 1880-1885

出版社

WILEY-V C H VERLAG GMBH
DOI: 10.1002/jssc.201100230

关键词

GC-MS; Organophosphorous pesticides; Pneumatic nebulization; Solvent microextraction; Water analysis

向作者/读者索取更多资源

Organophosphorous pesticides (OPPs) including dichlorvos, diazinon, malathion, phenamiphos and chlorpyrifos, in water samples were extracted by pneumatic nebulization single-drop microextraction (PN-SDME) and then determined by gas chromatography mass spectrometry (GC-MS). Experimental parameters affecting the performances of PN-SDME, such as flow rate of carrier gas, extraction time and micro-drop volume, were examined and optimized. The limits of detection for the analytes were in the range of 0.0014-0.0019 mu g/mL. The linear range was 0.0050-0.50 mu g/mL, except dichlorvos (0.0070-0.50 mu g/mL). Water samples were analyzed and the recoveries of the analytes in the spiked water samples were from 75.2 to 105.3%. The relative standard deviations were lower than 12.7%.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.5
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据