期刊
JOURNAL OF SEPARATION SCIENCE
卷 31, 期 5, 页码 872-880出版社
WILEY-V C H VERLAG GMBH
DOI: 10.1002/jssc.200700593
关键词
capillary electrophoresis; in-line SPE; naproxen; sample preconcentration; tap water samples
SPE coupled in-line to CE, as the strategy to enhance the concentration sensitivity in CE, has been used to enrich naproxen in tap water samples. In this study, a micro cartridge containing an octadecyl silica (C-18) sorbent was placed near the inlet within the separation capillary column. The optimum conditions were obtained when naproxen in an acidic aqueous solution (pH 3.5) was loaded into the capillary at 930 mbar for 30 min, and 20 mM ammonium acetate in methanol/water (70:30 v/v) was used as both an elution solution and a separation BGE. Under these conditions, the sensitivity was enhanced 1820-fold with respect to normal hydrodynamic injection, and the LOD achieved was 0.2 mu g/L. To show the capability of the in-line SPE-CE method, tap water samples were analysed after a pretreatment consisting in an off-line C-18-SPE procedure. The recovery of this procedure was higher than 80%. Under these conditions, naproxen could be detected at a concentration of 10ng/L; so the potential of the procedure for the sensitive analysis of this type of drugs in water samples was demonstrated. Afterwards, these results were compared with those previously obtained for naproxen in water samples using different sample stacking techniques.
作者
我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。
推荐