4.5 Article

Hybrid grafted ion exchanger for decontamination of radioactive cesium in Fukushima Prefecture and other contaminated areas

期刊

出版社

SPRINGER
DOI: 10.1007/s10967-012-1721-2

关键词

Cesium decontamination; Radiation-induced graft polymerization; Ammonium 12-molybdophosphate; Nonwoven fabric; Column chromatography

资金

  1. Ministry of Education, Culture, Sports, Science and Technology

向作者/读者索取更多资源

We have developed a material that can be used to remove cesium (Cs) in Fukushima Prefecture and other contaminated areas. The developed material was prepared by radiation-induced graft polymerization of ammonium 12-molybdophosphate and acrylonitrile onto nonwoven polyethylene fabric. To evaluate the adsorption performance of the developed material, we conducted batch and column experiments by using a Cs solution with a concentration of 1 ppm at pH 7. In the batch study, the adsorbent was able to remove 90, 87 and 64 % of Cs from pure water, acidic water and seawater, respectively. In the column study, adsorbent packed in a column with a diameter of 7 mm and a height of 5 cm was able to remove nearly the entire amount of dissolved Cs. The solution (1 ppm Cs at pH 7) was pumped into the column at a space velocity of 300 h(-1), in which the Cs adsorption capacity at the breakthrough point reached 54 g-Cs/kg-adsorbent. Adsorbent grafted into a cartridge with a diameter of 4 cm and a height of 3.8 cm was used in a field test on removing dissolved radioactive Cs in Iitate-mura, and this test was conducted successfully.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.5
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据