4.8 Article

Open circuit voltage profiling as diagnostic tool during stack lifetime testing

期刊

JOURNAL OF POWER SOURCES
卷 195, 期 15, 页码 4928-4934

出版社

ELSEVIER SCIENCE BV
DOI: 10.1016/j.jpowsour.2009.12.061

关键词

Fuel cells; Diagnostic tools; Current mapping; OCV

向作者/读者索取更多资源

A 10-cell Mk 9 stack was characterized using current/voltage mapping during automotive drive cycle testing. A minimally invasive current mapping technique was used to determine localized polarization curves which together with open circuit voltage (OCV) profile measurements provide useful information about crossover leak formation and location. Through a systematic variation of reactant gas pressures it is further possible to distinguish between electrical shorts, diffusive and convective leaks. (C) 2010 Published by Elsevier B.V.