4.6 Article

Measurements of the Equilibrium Size of Supersaturated Aqueous Sodium Chloride Droplets at Low Relative Humidity Using Aerosol Optical Tweezers and an Electrodynamic Balance

期刊

JOURNAL OF PHYSICAL CHEMISTRY A
卷 114, 期 4, 页码 1806-1815

出版社

AMER CHEMICAL SOC
DOI: 10.1021/jp9095985

关键词

-

资金

  1. EPSRC
  2. NSERC of Canada
  3. Canada-United Kingdom Millennium Research
  4. NSFC [20873006]
  5. APPRAISE program
  6. Engineering and Physical Sciences Research Council [EP/F002122/1, EP/G007713/1] Funding Source: researchfish
  7. Natural Environment Research Council [appraise010003, NE/E002641/1] Funding Source: researchfish
  8. EPSRC [EP/F002122/1, EP/G007713/1] Funding Source: UKRI
  9. NERC [appraise010003, NE/E002641/1] Funding Source: UKRI

向作者/读者索取更多资源

An approach for examining the hygroscopicity of single aerosol particles over I broad range in relative humidity (RH) using aerosol optical tweezers is presented and compared with measurements made using an electrodynamic balance. In particular. benchmark measurements oil aqueous sodium chloride aerosol are presented over the RH range 45-75% (293 K), a RH range that had not previously been explored with aerosol optical tweezers. Measurements of the variation in equilibrium wet droplet size with RH are made using cavity-enhanced Raman scattering. with all accuracy of 1 nm in the determination of the wet particle radius. The Full range of optical tweezers experimental measurements (including previous dual trapping comparative studies approaching a saturation relative humidity of 100%) are compared with determinations using other experimental techniques and with a range of model treatments. An assessment of the models and all experimental data for estimating the equilibrium size of a sodium chloride droplet suggests that the size can be predicted with all accuracy of better than 0.1% over the RH range 48-100%. Discrepancies between different measurements lead to all increase ill uncertainty above 1% below all RH of 48% as efflorescence is approached. The optical tweezers' measurements of equilibrium size consistently agree with model predictions to within an error of 1% (<50 nm for the size range explored here) and mostly with all error of less than +/- 0.1%. These data demonstrate the highly accurate nature of measurements of thermodynamic equilibrium size by aerosol Optical tweezers and suggest that this approach may be used to investigate the competition between thermodynamic and kinetic factors ill governing aerosol particle size over the full RH range.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.6
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据