4.6 Article

Solid phase microextraction-Liquid chromatography (SPME-LC) determination of chloramphenicol in urine and environmental water samples

期刊

出版社

ELSEVIER
DOI: 10.1016/j.jpba.2010.05.011

关键词

SPME; LC-UV; Chloramphenicol; Urine; Water

向作者/读者索取更多资源

A solid phase microextraction liquid chromatography with ultraviolet detection (SPME-LC-UV) method for the determination of the antimicrobial agent chloramphenicol was developed The performances of three commercially available fibers were compared; the Carbowax/TPR-100 was found to provide the most efficient extraction. All the aspects influencing the fiber adsorption (extraction time, temperature, pH, salt addition) and desorption (desorption and injection time, desorption solvent mixture composition) of the analyte were investigated The method was eventually applied to the determination of the drug in both biological (urine) and environmental (tap and sea water) samples The optimized procedure required a simple sample pretreatment, isocratic elution, and provided enough sensitivity for the analyte determination in the considered samples The investigated linear ranges were 37-1000 ng/ml (urine), 0.1-10 ng/ml (tap water), 0 3-30 ng/ml (sea water) Within-day and between-days RSD% ranged between 5 5-6 2 and 87-9.0 (urine), 5 1-6 0 and 8.4-8.8 (tap water), 5 4-5 7 and 8 6-8.9 (sea water) Estimated LOD and LOQ were 37 and 95 ng/ml (urine), 0 1 and 0.3 ng/ml (tap water), 0.3 and 0.7 ng/ml (sea water) (c) 2010 Elsevier B V All rights reserved.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.6
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据