4.6 Article Proceedings Paper

Development and validation of a liquid chromatographic method for the determination of ascorbic acid, dehydroascorbic acid and acetaminophen in pharmaceuticals

期刊

出版社

ELSEVIER SCIENCE BV
DOI: 10.1016/j.jpba.2008.01.026

关键词

reversed-phase liquid chromatography (RP-LC); 4,5-Dimethyl-1,2-phenylendiamine (DMPD); validation; dehydroascorbic acid (DHA); ascorbic acid (AA); acetaminophen; pharmaceuticals

向作者/读者索取更多资源

A reversed-phase ion pair liquid chromatographic method (RP-LC) for the determination of dehydroascorbic acid (DHA) and ascorbic acid (AA) and also acetaminophen, which is combined in pharmaceuticals. is proposed and validated. AA and acetaminophen were analyzed directly, while DHA was determined after pre-column derivatization with 4,5-dimethyl-1,2-phenylenediamine (DMPD). The derivatization reaction was carried out under mild conditions (10 min at ambient temperature) in the dark in sodium acetate buffer (80 mM; pH 3.7) solution containing EDTA as metal scavenger. The chromatographic separations were performed on a Phenomenex Synergi 4u hydro-RP (150 mm x 4.6 mm) under isocratic elution conditions, using cetyltrimethylammonium bromide (CTAB) as ion-pairing reagent in the mobile phase. Linear responses were observed for each compound. The intra-day precision (R.S.D.) was <= 1.40% and there was no significant difference between intra- and inter-day data. Recovery studies showed good results for all compounds (99.7-101.8%) with R.S.D. ranging from 0.56 to 1.82%. The limits of quantitation were about 40, 50 and 140 pmol for acetaminophen, AA and DHA, respectively. The DHA impurity values found in dosage forms were <= 0.2% of AA. (C) 2008 Elsevier B.V. All rights reserved.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.6
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据