4.6 Article

Development and validation of GC-MS method for the determination of methyl methane sulfonate and ethyl methanesulfonate in imatinib mesylate

期刊

出版社

ELSEVIER SCIENCE BV
DOI: 10.1016/j.jpba.2007.11.013

关键词

development; validation; mesylate esters; imatimb mesylate

向作者/读者索取更多资源

A gas chromatography-mass spectrometry (GC-MS) method has been developed for the identification and determination of two carcinogenic and genotoxic mesylate esters viz. methyl methanesulfonate (MMS) and ethyl methanesulfonate (EMS) in imatinib mesylate (INM). The method was optimized based on the peak shapes and resolution of MMS and EMS. The method was validated as per International Conference of Harmonization (ICH) guidelines in terms of limits of detection (LOD), limit of quantitation (LOQ), linearity, precision, accuracy, specificity and robustness. The LOD and LOQ values were found to be 0.3 and 1.0 mu g/ml, respectively. The method is linear within the range of 1-15 mu g/ml for both the compounds. These mesylate esters were not found in three different batches of pure and pharmaceutical formulations of INM. (C) 2007 Elsevier B.V. All rights reserved.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.6
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据