4.6 Article

Continuous Glucose Monitoring in Newborn Babies at Risk of Hypoglycemia

期刊

JOURNAL OF PEDIATRICS
卷 157, 期 2, 页码 198-202

出版社

MOSBY-ELSEVIER
DOI: 10.1016/j.jpeds.2010.02.003

关键词

-

资金

  1. Auckland Medical Research Foundation
  2. Waikato Medical Research Foundation
  3. Rebecca Roberts Scholarship

向作者/读者索取更多资源

Objective To determine the usefulness of continuous glucose monitoring in babies at risk of neonatal hypoglycemia. Study design Babies >= 32 weeks old who were at risk of hypoglycemia and admitted to newborn intensive care received routine treatment, including intermittent blood glucose measurement using the glucose oxidase method, and blinded continuous interstitial glucose monitoring. Results Continuous glucose monitoring was well tolerated in 102 infants. There was good agreement between blood and interstitial glucose concentrations (mean difference, 0.0 mmol/L; 95% CI, -1.1-1.1). Low glucose concentrations (< 2.6 mmol/L) were detected in 32 babies (32%) with blood sampling and in 45 babies (44%) with continuous monitoring. There were 265 episodes of low interstitial glucose concentrations, 215 (81%) of which were not detected with blood glucose measurement. One hundred seven episodes in 34 babies lasted > 30 minutes, 78 (73%) of which were not detected with blood glucose measurement. Conclusion Continuous interstitial glucose monitoring detects many more episodes of low glucose concentrations than blood glucose measurement. The physiological significance of these previously undetected episodes is unknown. (J Pediatr 2010; 157: 198-202).

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.6
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据