4.7 Article

Identification and application of ssDNA aptamers against H37Rv in the detection of Mycobacterium tuberculosis

期刊

APPLIED MICROBIOLOGY AND BIOTECHNOLOGY
卷 99, 期 21, 页码 9073-9083

出版社

SPRINGER
DOI: 10.1007/s00253-015-6815-7

关键词

Evolution; Whole cell SELEX; ssDNA aptamer; Mycobacterium tuberculosis; Detection

资金

  1. Ministry of Science and Technology of the People's Republic of China [2012ZX10003002-008]
  2. Science and Technology Commission of Shanghai Municipality, Shanghai, People's Republic of China [124119a1500]
  3. National Natural Science Foundation of China [81201254, 81470090]

向作者/读者索取更多资源

Microscopy of direct smear with the Ziehl-Neelsen stain is still broadly used in tuberculosis diagnosis. However, this method suffers from low specificity and is difficult to distinguish Mycobacterium tuberculosis (MTB) from nontuberculosis mycobacterial (NTM), since all mycobacterial species are positive in Ziehl-Neelsen stain. In this study, we utilized whole cell SELEX to obtain species-specific aptamers for increasing the specificity of MTB detection. Whole cell SELEX was performed in MTB reference strain H(37)Rv by two selection processes based on enzyme-linked plate or Eppendorf tube, respectively. To increase success rate of generating aptamers, the selection processes were systematically monitored to understand the dynamic evolution of aptamers against complex structure of target bacteria. Two preponderant groups and ten high-affinity aptamers were obtained by analyzing the dynamic evolution. Preponderant aptamer MA1 from group I showed relatively high binding affinity with apparent dissociation constant (K-D value) of 12.02 nM. Sandwich ELISA assay revealed five aptamer combinations effectively bound MTB strains in preliminary evaluation, especially the combination based on aptamer MA2 (another preponderant aptamer from group II) and MA1. Further evaluated in many other strains, MA2/MA1 combination effectively identified MTB from NTM or other pathogenic bacteria, and displayed the high specificity and sensitivity. Binding analysis of aptamer MA1 or MA2 by fluorescence microscopy observation showed high binding reactivity with H(37)Rv, low apparent cross-reactivity with M. marinum, and no apparent cross-reactivity with Enterobacter cloacae. Taken together, this study provides attractive candidate species-specific aptamers to effectively capture or discriminate MTB strains.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.7
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据