4.7 Article

68Ga PET/CT Ventilation-Perfusion Imaging for Pulmonary Embolism: A Pilot Study with Comparison to Conventional Scintigraphy

期刊

JOURNAL OF NUCLEAR MEDICINE
卷 52, 期 10, 页码 1513-1519

出版社

SOC NUCLEAR MEDICINE INC
DOI: 10.2967/jnumed.111.093344

关键词

PET/CT; ventilation; perfusion; V/Q; Ga-68; pulmonary embolism

向作者/读者索取更多资源

Ventilation-perfusion (V/Q) scintigraphy is established for regional assessment of lung function in a variety of diseases, including pulmonary embolism (PE). PET/CT may further improve the accuracy and utility of V/Q imaging because of its superior technical characteristics. This pilot study assessed the feasibility of performing V/Q PET/CT and compared diagnostic utility with conventional V/Q imaging in patients with clinical suspicion of PE. Methods: Ten patients undergoing conventional V/Q imaging were prospectively recruited. PET/CT V/Q imaging was performed after inhalation of Ga-68-carbon nanoparticles (Galligas) and administration of Ga-68-macroaggregated albumin. Blinded to the results of the other study, SPECT/CT (n = 9) or SPECT (n = 1) images and PET/CT images were graded by a predefined scoring system for scan quality. The number of matched or unmatched defects and diagnosis were also measured and compared with a final diagnosis. Results: PET image quality was equivalent or superior to SPECT in all patients, with more homogeneous radiotracer distribution for both ventilation and perfusion studies (P < 0.01). Based on conventional V/Q imaging, the diagnosis was acute PE in 2 patients and no PE in 7 patients, and the imaging results were nondiagnostic in 1 patient. The PET/CT diagnosis was concordant in 8 patients, and these studies demonstrated a similar number and distribution of matched and unmatched defects. In 1 discordant case, a patient with a SPECT/CT study that was nondiagnostic because of severe airway disease showed no PE on PET/CT. In another, the diagnosis of PE established on SPECT/CT was not reported on PET/CT 2 d later, possibly because of interval clot lysis or migration. Conclusion: This intraindividual comparative study demonstrated that V/Q PET/CT with Ga-68-labeled radiotracers can be performed in clinical practice. Compared with conventional V/Q imaging, advantages include higher-resolution, fully tomographic images with potentially better regional quantitation of lung function. The short half-life of Ga-68 also enables more flexible acquisition protocols with the option of performing ventilation studies selectively on patients with abnormal perfusion. On the basis of our results, further studies are indicated to assess whether V/Q PET/CT can improve diagnostic algorithms for patients with suspected PE.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.7
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据