4.6 Article

A dynamic nonlinear relationship between the static and pulsatile components of intracranial pressure in patients with subarachnoid hemorrhage

期刊

JOURNAL OF NEUROSURGERY
卷 112, 期 3, 页码 616-625

出版社

AMER ASSOC NEUROLOGICAL SURGEONS
DOI: 10.3171/2009.7.JNS081593

关键词

intracranial pressure; static intracranial pressure; intracranial pulsatility; pressure-volume curve; compliance

资金

  1. NIGMS NIH HHS [T32 GM007753] Funding Source: Medline

向作者/读者索取更多资源

Object. In the search for optimal monitoring and predictive tools in neurocritical care, the relationship of the pulsatile component of intracranial pressure (ICP) and the pressure itself has long been of great interest. Higher pressure often correlates with a higher pulsatile response to the heartbeat, interpreted as a type of compliance curve. Various mathematical approaches have been used, but regardless of the formula used, it is implicitly assumed that a reproducible curve exists. The authors investigated the stability of the correlation between static and pulsatile ICPs in patients with subarachnoid hemorrhage (SAH) who were observed for several hours by using data sets large enough to allow such calculations to be made. Methods. The ICP recordings were obtained in 39 patients with SAH and were parsed into 6-second time windows ( 1,998,944 windows in 197 recordings). The ICP parameters were computed for each window as follows: static ICP was defined as the mean ICP, and pulsatile ICP was characterized by mean ICP wave amplitude, rise time, and rise time coefficient. Results. The mean ICP and ICP wave amplitudes were simultaneously high or low ( the expected correlation) in only similar to 60% of observations. Furthermore, static and pulsatile ICP correlated well only over short intervals; the degree of correlation weakened over periods of hours and was inconsistent across patients and within individual patients over time. Decorrelation originated with abrupt shifting and gradual drifting of mean ICP and ICP wave amplitude over several hours. Conclusions. The relationship between the static and pulsatile components of ICPs changes over time. It evolves, even in individual patients, over a number of hours. This can be one reason the observation of high pulsatile ICP ( indicative of reduced intracranial compliance) despite normal mean ICP that is seen in some patients with SAH. The meaning and potential clinical usefulness of such changes in the curves is uncertain, but it implies that clinical events result not only from moving further out on a compliance curve; in practice, the curve, and the biological system that underlies the curve, may itself change. (DOI: 10.3171/2009.7.JNS081593)

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.6
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据