4.4 Article

Cognitive tasks and human ambulatory electrocorticography using the RNS System

期刊

JOURNAL OF NEUROSCIENCE METHODS
卷 311, 期 -, 页码 408-417

出版社

ELSEVIER SCIENCE BV
DOI: 10.1016/j.jneumeth.2018.09.026

关键词

RNS System; Memory; Navigation; Ambulatory ECoG; ECoG; Electrocorticography; Epilepsy; Cognition

资金

  1. National Institutes of Health [R01-NS074450]
  2. National Science Foundation [EPSCoR-1632738]

向作者/读者索取更多资源

Background: Electrocorticography studies are typically conducted in patients undergoing video EEG monitoring, but these studies are subject to confounds such as the effects of pain, recent anesthesia, analgesics, drug changes, antibiotics, and implant effects. New method: Techniques were developed to obtain electrocorticographic (ECoG) data from freely moving subjects performing navigational tasks using the RNS (R) System (NeuroPace, Inc., Mountain View, CA), a brain responsive neurostimulation medical device used to treat focal onset epilepsy, and to align data from the RNS System with cognitive task events with high precision. These subjects had not had recent surgery, and were therefore not confounded by the perioperative variables that affect video EEG studies. Results: Task synchronization using the synchronization marker technique provides a quantitative measure of clock uncertainty, and can align data to task events with less than 4 ms of uncertainty. Hippocampal ECoG activity was found to change immediately before an incorrect response to a math problem compared to hippocampal activity before a correct response. In addition, subjects were found to have variable but significant changes in theta band power in the hippocampus during navigation compared to when subjects were not navigating. We found that there is theta gamma phase-amplitude coupling in the right hippocampus while subjects stand still during a navigation task. Comparison with existing methods: An alignment technique described in this study improves the upper bound on task-ECoG alignment uncertainty from approximately 30 ms to under 4 ms. The RNS System is one of the first platforms capable of providing untethered ambulatory ECoG recording in humans, allowing for the study of real world instead of virtual navigation. Compared to intracranial video EEG studies, studies using the RNS System platform are not subject to confounds caused by the drugs and recent surgery inherent to the perioperative environment. Furthermore, these subjects provide the opportunity to record from the same electrodes over the course of many years. Conclusions: The RNS System enables us to study human navigation with unprecedented clarity. While RNS System patients have fewer electrodes implanted than video EEG patients, the lack of external artifact and confounds from recent surgery make this system a useful tool to further human electrophysiology research.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.4
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据