4.4 Article

Rectification of the EMG Signal Impairs the Identification of Oscillatory Input to the Muscle

期刊

JOURNAL OF NEUROPHYSIOLOGY
卷 103, 期 2, 页码 1093-1103

出版社

AMER PHYSIOLOGICAL SOC
DOI: 10.1152/jn.00792.2009

关键词

-

资金

  1. National Institute on Aging [R01 AG-031769]

向作者/读者索取更多资源

Neto OP, Christou EA. Rectification of the EMG signal impairs the identification of oscillatory input to the muscle. J Neurophysiol 103: 1093-1103, 2010. First published December 23, 2009; doi:10.1152/jn.00792.2009. Rectification of EMG signals is a common processing step used when performing electroencephalographic-electromyographic (EEG-EMG) coherence and EMG-EMG coherence. It is well known, however, that EMG rectification alters the power spectrum of the recorded EMG signal (interference EMG). The purpose of this study was to determine whether rectification of the EMG signal influences the capability of capturing the oscillatory input to a single EMG signal and the common oscillations between two EMG signals. Several EMG signals were reconstructed from experimentally recorded EMG signals from the surface of the first dorsal interosseus muscle and were manipulated to have an oscillatory input or common input (for pairs of reconstructed EMG signals) at various frequency bands (in Hz: 0-12, 12-30, 30-50, 50-100, 100-150, 150-200, 200-250, 250-300, and 300-400), one at a time. The absolute integral and normalized integral of power, peak power, and peak coherence (for pairs of EMG signals) were quantified from each frequency band. The power spectrum of the interference EMG accurately detected the changes to the oscillatory input to the reconstructed EMG signal, whereas the power spectrum of the rectified EMG did not. Similarly, the EMG-EMG coherence between two interference EMG signals accurately detected the common input to the pairs of reconstructed EMG signals, whereas the EMG-EMG coherence between two rectified EMG signals did not. The frequency band from 12 to 30 Hz in the power spectrum of the rectified EMG and the EMG-EMG coherence between two rectified signals was influenced by the input from 100 to 150 Hz but not from the input from 12 to 30 Hz. The study concludes that the power spectrum of the EMG and EMG-EMG coherence should be performed on interference EMG signals and not on rectified EMG signals because rectification impairs the identification of the oscillatory input to a single EMG signal and the common oscillatory input between two EMG signals.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.4
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据