4.7 Article

The value of skin biopsy with recording of intraepidermal nerve fiber density and quantitative sensory testing in the assessment of small fiber involvement in patients with different causes of polyneuropathy

期刊

JOURNAL OF NEUROLOGY
卷 256, 期 7, 页码 1067-1075

出版社

DR DIETRICH STEINKOPFF VERLAG
DOI: 10.1007/s00415-009-5065-y

关键词

Intraepidermal nerve fiber density; Quantitative sensory testing; ROC analysis; Small fiber polyneuropathy; Z-scores

资金

  1. Regional Health Authority of North Norway and Faculty of Medicine
  2. University of Tromso

向作者/读者索取更多资源

The primary aim of our study was to demonstrate how the diagnostic characteristics of skin biopsy used to evaluate small fiber involvement in patients with different causes of polyneuropathy are intrinsically related to the method used to establish the reference values (cut-off values). We also investigated intraepidermal nerve fiber (IENF) density and abnormalities in quantitative sensory testing (QST) in patients with different causes of polyneuropathy and signs of small fiber involvement. A total of 210 patients with symptoms and signs of polyneuropathy were entered into the study. All patients underwent neurological examination, nerve conduction studies, QST on the thigh and distal part of the calf with detection of warm and cold perception thresholds, and skin biopsy with assessment of IENF density. Cut-off values for IENF density were established from our reference material using Z-scores (calculated from multiple regression analysis), fifth percentile, and receiver operating characteristic (ROC) analysis. Of the patients participating in the study, 65 had an established diagnosis of diabetes mellitus, 70 were classified with idiopathic polyneuropathy, and 75 had other possible causes of polyneuropathy. Forty-five patients met the criteria for small fiber polyneuropathy (SFN), and the remaining 165 had also involvement of large nerve fibers. Of the total patient cohort, 84 (40%) had reduced IENF density based on the Z-score, and 106 patients (50%) had at least one abnormality based on QST. In the SFN group, skin biopsy showed a sensitivity of 31% and a specificity of 98% when reference values were presented with Z-scores. When the fifth percentile was used as the cut-off value (6.7 fibers/mm), sensitivity was 35% and specificity 95%. Applying the ROC analysis with a chosen sensitivity of 78% and specificity of 64%, we had a cut-off point of 10.3 fibers/mm. We conclude that skin biopsy with assessment of IENF is a useful method for investigating patients with SFN. The diagnostic value of the test, however, depends upon on the approach used to estimate the reference values.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.7
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据