4.5 Article

Definition of a new cut-off for the anti-phospholipase A2 receptor (PLA2R) autoantibody immunoassay in patients affected by idiopathic membranous nephropathy

期刊

JOURNAL OF NEPHROLOGY
卷 31, 期 6, 页码 899-905

出版社

SPRINGER HEIDELBERG
DOI: 10.1007/s40620-018-0533-z

关键词

Anti-phospholipase A2 receptor (PLA2R) antibody; Membranous nephropathy; Enzyme-linked immunosorbent assay (ELISA); Receiver operating characteristic (ROC); Cut-off value

向作者/读者索取更多资源

Autoantibodies against phospholipase A2 receptor (PLA2R) are a sensitive and specific marker for idiopathic membranous nephropathy (IMN). The aim of our study was to redefine the cut-off value for the measurement of anti-PLA2R autoantibody levels by an automated enzyme immunoassay, in a large single-center cohort of Italian IMN patients at the time of diagnosis. Sixty-seven consecutive incident patients, with biopsy-proven IMN, were recruited. All patients were naive to preceding immunosuppressive therapeutic regimens. The patient population had a mean age of 57years and included 48 males and 19 females. Also, 200 patients with other renal diseases and 36 healthy subjects were studied as controls. The anti-PLA2R autoantibody levels were measured using the commercial enzyme-linked immunosorbent assay kit at the time of renal biopsy. At a cut-off value of 2.7RU/ml (significantly lower than the manufacturer's recommended value of 14RU/ml), calculated by receiver operating characteristic curves, the sensitivity and specificity of anti-PLA2R autoantibodies in the diagnosis of IMN was 88.1 and 96% respectively. The adapted cut-off value of 2.7UI/ml increased sensitivity without affecting the specificity and it should be the recommended value for this method. Additionally our study confirmed the correlation, at baseline, between anti-PLA2R autoantibody levels and other biomarkers of disease activity.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.5
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据